Spray Foam Insulation Community Portal and Guide
HOME      FIND CONTRACTORS      SUPPLIER DIRECTORY      Q & A FORUMS      NEWS & EVENTS      MEDIA & PROMOTIONS      ABOUT SPRAYFOAM
Share
Browse Categories
Business Directory
Foam Systems
Soy Based Foam Systems
 
Ads by SprayFoam.com
     
FREE Classified Ads
 
Buy or Sell Used Equipment and Foam Supplies. Free to Registered Users of SprayFoam.com. Manage Your Ads.
 
 
     
New Foam Business Owners Enjoy Immediate Rewards
 
New business owners enjoy immediate rewards when becoming an AirTight Licensed Applicator. Find out more...
 
 
 
 
 
 
Spray Foam Insulation >> Closed Cell vs. Open Cell Foam

Closed Cell vs. Open Cell Foam

What is the Difference between Open-cell and Closed-cell Polyurethane Foams?
This may be one of the most important pages on the website if your interest is in spray foam insulation. When it comes time to actually put the foam product in your home or commercial building structure, you must identify whether you will use 0.5 lb./cu. ft., open cell foam, or 2.0 lb./cu. ft. closed cell foam. This makes a big difference in cost, application methods, and performance.

With the open-cell vs. closed-cell issue, there are two major factors to understand and consider. The first is the nature of the foam. It is either open-cell foam, where the tiny cells of the foam are not completely closed. They are broken and air fills all of the “open” space inside the material. This makes the foam weaker or softer feeling than closed-cell foam.

Closed-cell foam differs in that all of its tiny foam cells are closed and packed together. They are filled with a gas that helps the foam rise and expand and become a greater insulator. These cells can be formulated to obtain many characteristics, the most common being size and density.

Density is measured by weighing one solid cubic foot of foam material. Open cell foams typically weigh in at 0.4 to 0.5 lb./cu. ft. Closed cell foam for insulation applications range in density from 1.7 lb./cu. ft. to 2.0 lb./cu. ft. Roofing applications typically use a 2.8 to 3.0+ lb./cu. ft. to support traffic and loads better. The higher the density the foam, the heavier, or stronger it becomes. Some polyurethane foams are molded into decorative interior molding and painted or stained for a simulated wood effect. These “higher density” foams are typically in the 30 lb./cu. ft. to 40 lb./cu. ft. density range.

 

The advantages of closed-cell foam compared to open-cell foam include its strength, higher R-value, and its greater resistance to the leakage of air or water vapor. The disadvantage of the closed-cell foam is that it is denser, requires more material, and therefore, is more expensive. Even though it has a better R-value, typically the cost per R is still higher than open-cell foam. The choice of foam can also be based on the requirements for the other performance or application specific characteristics such as strength, vapor control, available space, etc.  Open-cell SPF has an R-value around 3.5 per inch and typically uses water as the blowing agent.  Closed-cell SPF has an R-value of around 6.0 per inch (aged R-value) and uses high R-value blowing agents.

 

Both types of foam are commonly used in most building applications and the choice for which to use can depend on many of the factors discussed above. Some foams are inappropriate in specific applications. For example, you typically would not use open-cell foam below grade or in flotation applications where it could absorb water; this would negate its thermal performance because water is a poor insulator compared to air. Closed-cell foam would be a good choice where small framing sizes need the greatest R-value per inch possible. Closed-cell foam would be used for roofing applications.

 

Always contact your material supplier for performance and application data on their specific materials. What type of foam being used in your building or home is always a good issue to discuss with your spray foam contractor up front, before the job starts.

 

 
 
 
SPF Documents
Learning the Difference Between 1/2-lb and 2-lb Spray Polyurethane Foam
Residential Closed-Cell Spray Foam Insulation Facts
 
 
 
 
 
 


 
Video Directory
Closed Cell Spray Foam vs. Open Cell Spray Foam Movie
 
 
 
 
 
 
 
 
SprayFoam.com Advertisers Showcase
 
SprayFoam.com Media Kit
 
News & Info News  |  Industry Events  |  Public Announcements  |  Blogs  |  Community Columns / Newsletters  |  Feature Articles  |  Answers & FAQs  |  RSS    
 
SPF Guides Architect's Guide  |  Homeowner's Guide  |  Becoming an SPF Contractor  |  Training Schools  |  Foam Equipment Guide  |  Technical Documents
 
Marketplace Contractor Finder  |  Business Directory  |  Jobs Market  |  Classifieds  |  Promotional Offers  |  Contests & Registrations  | Spray Foam Product Mall    
 
Community Video Directory |  Photo Galleries  |  Q&A Forums  |  Networking  |  Postcards  |  My Account  |  Join Our Email Lists    

 
Home  |   Site Index  |   Privacy Policy  |   Terms of Service  |   Advertising/Media Kit  |   Contact Us
  © SprayFoam.com, Inc. All Rights Reserved
arcteryxhandbags louis vuitton handbags chanel handbags gucci handbags north face
briquette machinebriquette machine